★★★★★ 5.0 from 100+ Google reviews · Your Sydney Plumber

Bosch hot water error codes: what EA, A7, E9 and others mean

On Bosch gas continuous flow units, EA means the burner didn't light or the unit couldn't detect a flame. Bosch's first step is to check the gas is on, then turn the unit off at the power point for a short time and restart it (the manuals give 10 to 30 seconds, depending on the model). If EA keeps coming back, or you see codes like A7 (a hot water temperature sensor fault), it needs a licensed gasfitter.

Bosch gas hot water units in Australia show a short letter-and-number code when they shut themselves down for safety. Some codes clear with a simple check you can do yourself. Others point to a part inside the unit that only a licensed gasfitter should touch. One catch: the same code can mean different things on different Bosch models, so it pays to know which unit you have before acting on a code. This page sets out what Bosch's own Australian manuals say, what you can safely try, and when to call us. We're an independent, licensed plumbing and gasfitting business based in Matraville, looking after homes across the Eastern Suburbs and Botany Bay.

Which Bosch unit do you have?

Bosch has sold several gas continuous flow (instantaneous) ranges in Australia over the years. The model name and a model number starting with GWH or TF are printed on the rating label on the side or front of the unit. Take a photo of that label before you do anything else. It tells you, and us, exactly which manual applies.

OptiFlow and HighFlow

Outdoor, wall-mounted gas units with a digital display (OptiFlow models were sold in 16, 20 and 26 litre-per-minute sizes). Bosch says it no longer sells these ranges, but it still supports them with spare parts and warranty.

Internal Compact

A smaller gas unit made to be installed indoors with a flue, in 10, 13 and 16 litre sizes. It has a temperature selector and a small display that shows codes such as EA, E9 and F0.

Pilot Ignition

An outdoor gas unit with a standing pilot flame (models such as TF250 and TF400). It has no digital fault codes. If the pilot goes out, Bosch's manual lets the owner relight it.

Bosch hot water in Australia is still sold and supported by Bosch itself, under the Bosch Home Comfort name (Robert Bosch (Australia) Pty Ltd). If your unit is still under warranty, contact Bosch's customer service team first. They arrange warranty repairs through their own service network, and the manuals warn that poor maintenance or non-genuine parts can affect the warranty.

First checks you can safely do

Before you book anyone, these checks follow what Bosch tells owners to do. None of them involve opening the unit.

  1. Write down the code exactly as it shows on the display or controller, and take a photo of the rating label.
  2. Turn all hot taps off. Bosch notes some units show a fault if the power is switched on while a hot tap is running.
  3. Check the gas. On natural gas, make sure the valve at the gas meter is open and your other gas appliances (cooktop, heater) are working. On LPG, check the cylinder isn't empty and its valve is open.
  4. Check the power. Make sure the power point the unit plugs into is switched on and the safety switch at the switchboard hasn't tripped. If it keeps tripping, call an electrician.
  5. Restart the unit. For OptiFlow and HighFlow units, Bosch's advice is to switch off and unplug at the power point for at least 30 seconds, plug it back in and wait about a minute while it runs its self-check.
  6. Try a hot tap. Open the hot tap closest to the unit. After an LPG cylinder change, Bosch suggests opening the nearest hot tap for a few seconds, closing it, and repeating until hot water comes through, as air in the gas line can take a few tries to clear.
  7. If the code comes straight back, stop. Repeated resets won't fix a faulty part.

If you smell gas, don't try any of the above. Turn the gas off at the meter (or the LPG cylinder), open windows and doors, don't touch light switches or anything that could spark, leave the area and call a licensed gasfitter. For a leak at the meter itself, call Jemena on 131 909.

What the common Bosch codes mean

The table below is drawn from Bosch's Australian manuals for the OptiFlow outdoor units and the Internal Compact indoor units. Where a code means something different between the two, both are shown. If your model isn't one of these, check the manual for your model rather than guessing.

CodeOptiFlow / HighFlow (outdoor)Internal Compact (indoor)What you can do
EANo flame detectedSpark but the burner didn't light, or no flame signalCheck the gas is on (and LPG isn't empty), then restart. If it returns, call a gasfitter.
E0Control module faultIgnition failure (treat as EA)Unplug for about 10 seconds and restart. If it returns, call a gasfitter.
A7Hot water outlet sensor faultTemperature sensor wiring or sensor faultNeeds a licensed technician.
E1Hot water sensor has detected overheatingOutlet water over its safe limitLet it cool and try again (on the Compact, lower the temperature setting). If it returns, call us.
E9Thermal fuse has trippedTemperature limiter has trippedOptiFlow: needs a technician. Compact: wait 10 minutes and restart once; if it returns, call us.
A4Air temperature sensor faultFlue safety device has trippedOptiFlow: needs a technician. Compact: air the room, wait 10 minutes, restart once; if it happens again, call us.
E4Overheating detected around the burner, which can mean combustion gases are escapingNot listedTurn off and unplug. Don't restart it. Call a gasfitter straight away.
F7Flame detected while the unit is offFalse flame signalRestart once. If it returns, call a gasfitter (the flue may need checking for water getting in).
F0Not listedPower button pressed with a hot tap runningTurn the hot tap off, then back on.
CF / C1Blocked flue outlet or not enough air to startNot listedMake sure nothing (leaves, a stored item, a plant) is blocking the vents, then try a hot tap. If it returns, call us.
CAWater flow above the unit's maximumNot listedUsually high mains pressure. A plumber may need to fit a pressure limiting valve.
EF / FA / F9Wrong gas type, gas valve or solenoid faultNot listedNeeds a licensed gasfitter.

What about C6? We couldn't find C6 in Bosch's current Australian manuals for these units, so we won't guess at what it means on your heater. If you see C6 or another code not shown here, note it down, check the manual for your exact model (Bosch publishes them on its Australian website), or send us a photo of the display and label and we'll look into it.

Resetting a Bosch unit: what Bosch allows

Bosch designs its units to lock out when they find a fault, so they stay off until reset. On the OptiFlow range, Bosch says you can reset by pressing the on/off button or by unplugging the unit and plugging it back in, and some faults can be cleared by holding the reset button for three seconds. A full reset on OptiFlow needs a Bosch controller. On Pilot Ignition models, Bosch's manual includes a lighting procedure the owner can follow using the gas control and igniter buttons on the unit. See our guide to relighting a hot water pilot for general safety tips, and follow the steps printed in your Bosch manual. If the pilot keeps going out, Bosch says it needs a service visit.

What you shouldn't do: remove the front cover, adjust the gas valve, touch the flue safety device or keep resetting a unit that keeps faulting. Bosch is clear that installation, maintenance and repairs are for qualified technicians only, and that the flue safety device must never be switched off or modified.

When it's a job for a licensed gasfitter

  • Any code that returns after one restart with the gas and power confirmed on.
  • Sensor, fan, gas valve or control faults (A7, A0, C7, FA, EF and similar).
  • E4, any sign of soot or black marks around the flue, or yellow, lazy flames.
  • A gas smell near the unit or the meter.
  • Water leaking from the unit or its fittings. Bosch's advice is to close the water and gas isolation valves, then call a licensed technician.
  • Hot water that fluctuates or loses flow even after you've checked the tap aerators, which can point to scale in the heat exchanger or a supply problem.

We're licensed plumbers, drainers and gasfitters, and we work on Bosch units along with every other common brand. We'll find the cause and check parts availability for your model.

Repair or replace?

A single sensor or ignition fault on a newer unit is often worth repairing. It gets less clear-cut when the unit is older, parts for a discontinued range are slow to come, the heat exchanger is scaled or leaking, or you've had several faults in a row. A leaking heat exchanger usually means replacement. We'll give you both options side by side so you can decide.

If you're replacing, the main choices are:

  • Like-for-like gas continuous flow. Usually the simplest swap, often in the same spot, though older pipework sometimes needs upgrading.
  • A larger flow rate. If two showers at once leaves someone cold, a bigger unit may suit. Our hot water sizing guide explains how to choose.
  • Gas storage, electric or heat pump. Worth weighing if your gas supply is limited or you're moving away from gas. See our heat pump guide and gas hot water page for the trade-offs.

A job nearby: gas supply matters with continuous flow

The problem: In Maroubra, an old gas storage tank down the side of a home stopped delivering hot water. This was not a Bosch unit, and the owners chose a Rinnai continuous flow unit as the replacement.

What we did: We explained repair against replacement and the systems that would suit the home. We removed the tank, wall-mounted the new Rinnai unit, upsized the copper pipework and replaced the gas regulator at the meter so the unit could get enough gas.

The result: Reliable hot water at every tap. The lesson for any continuous flow unit, Bosch included: if the gas pipework or regulator is too small, the unit can struggle to light or hold temperature, so we check the gas supply as part of any replacement.

What affects the cost

We don't quote over the phone without seeing the unit, because the price depends on a few things:

  • Whether the fault is a simple part (a sensor or igniter) or a major one (heat exchanger or control module).
  • Whether parts are on hand for your model, as some older or discontinued ranges take longer.
  • Access to the unit, and whether it's outdoors or an indoor unit with a flue.
  • For replacements, the size and type of new system and whether gas pipework, the regulator or water connections need upgrading.
  • Whether the unit is still under Bosch's warranty, in which case Bosch should be your first call.

Whatever it is, you get options and a fixed price before we start, and a $0 call-out fee.

What to have ready when you call

  • A photo of the rating label (model and serial number).
  • The exact code on the display or controller, and whether it came back after a restart.
  • Roughly how old the unit is, and any purchase or service paperwork.
  • Whether you're on natural gas or LPG, and whether other gas appliances are working.

Local notes for Eastern Suburbs homes

Many Bosch outdoor units around Maroubra, Malabar, Coogee and Little Bay are mounted on walls that cop salt air off the ocean. Over time that can corrode outer casings, flue terminals and fittings, so a regular look and service matter more near the coast. Plenty of older brick homes in the area still have original copper or galvanised pipe, which can restrict water flow or leave the gas supply undersized for a modern continuous flow unit.

Keeping your Bosch unit running well

  • Book a service and safety inspection by a licensed technician. Bosch's manuals say every two years for outdoor OptiFlow and Pilot models, and every year for the Internal Compact.
  • Keep the area around the unit clear of leaves, rubbish and stored items, and keep plants trimmed back from the vents.
  • Don't spray insect spray, aerosols or chemicals near the unit while it's connected to power.
  • Clean the outside only with a soft cloth and mild detergent.
  • Check the water temperature with your hand before bathing children or older people. Bosch notes the display temperature is approximate.

What happens when you call

1

Tell us what's going on

Call or send a quick form. A photo of the unit's label and any code on the display helps us come prepared. No call-out fee.

2

Options and a fixed price first

We find the cause, explain repair and replacement options and give you a fixed price for each before any work starts.

3

Fixed, tested and backed

We do the work, test it, clean up, and back our workmanship with a lifetime labour warranty.

Why Eastern Suburbs homeowners call us

  • Based in Matraville, a short drive from homes across the Eastern Suburbs
  • Rated 5.0 from 110 Google reviews
  • Free quotes, with options and a fixed price before any work starts
  • Lifetime labour warranty on our workmanship
  • Licensed plumbers, drainers and gasfitters (Lic. 398171C)

Bosch hot water error code questions

What does EA mean on a Bosch hot water system?

On Bosch gas continuous flow units, EA means the burner hasn't lit or the unit can't detect a flame. Check the gas is on at the meter (or that your LPG cylinder isn't empty), then restart the unit at the power point. If EA keeps coming back, a licensed gasfitter needs to check the gas supply, igniter and flame sensor.

What does A7 mean on a Bosch unit?

A7 points to the hot water temperature sensor or its wiring. Bosch's manuals list it as a sensor fault, which isn't something an owner can fix. It needs a licensed technician.

How do I reset my Bosch hot water system?

On OptiFlow and HighFlow units, Bosch's advice is to turn off the hot taps, switch off and unplug the unit for at least 30 seconds, then plug it back in and wait about a minute. Some faults also clear by holding the reset button for three seconds. If the code returns, stop resetting and book a service.

Can I relight the pilot on my Bosch hot water unit?

On Bosch Pilot Ignition models, yes. The manual includes a lighting procedure for owners using the gas control and igniter buttons. If you smell gas, don't try. If the pilot keeps going out, Bosch says it needs a service visit.

Is Bosch still supporting hot water units in Australia?

Yes. Bosch Home Comfort (Robert Bosch (Australia) Pty Ltd) still sells and supports hot water in Australia. Bosch says it no longer sells the OptiFlow and HighFlow ranges, but still supplies spare parts and warranty support for them.

My Bosch is still under warranty. Who should I call?

Contact Bosch's customer service team first, with your invoice and the serial number handy. They arrange warranty repairs through their own service network. If it's out of warranty, or you'd like a second opinion, we're happy to help.

What does E4 mean, and is it dangerous?

On OptiFlow units, E4 means the unit has sensed overheating that can be caused by combustion gases escaping. Bosch says to switch off and unplug the unit, not restart it, and call for service straight away. Treat it seriously.

Should I repair or replace my Bosch hot water system?

It depends on the unit's age, which part has failed, whether parts are available, and whether the heat exchanger is leaking. We'll explain both options and give you a fixed price for each before any work starts, so you can choose.

See our main hot water repairs and replacement page and our gas hot water page, or get a hot water quote in 30 seconds. We look after Bosch units in Maroubra, Matraville and Coogee, plus suburbs across the Eastern Suburbs and Botany Bay.

Call 0401 758 373Free quote