AquaMAX hot water not heating? Safe checks and what to do next
When an AquaMAX stops heating, the cause is usually simple to narrow down. On a gas storage unit it's most often a pilot that has gone out or a gas supply problem. On an electric storage unit it's usually power at the switchboard, the off-peak tariff, or a failed element or thermostat. Do the safe checks below first. If they don't fix it, a licensed plumber or gasfitter should take a look, and we'll give you a fixed price before any work starts.
AquaMAX is an Australian hot water brand owned and made by Rheem, with its home at Rheem's Moorabbin factory in Victoria. It has been around since 1988, so there are plenty of AquaMAX units on the side of homes across the Eastern Suburbs and Botany Bay. The current range is electric vitreous enamel storage heaters (roughly 50 to 400 litres) and 5-star gas storage heaters with stainless steel cylinders. There's also an AquaMAX Pro-Tec gas continuous flow model, and older Pro-Tec gas and electric storage units are still in many homes. AquaMAX doesn't list a heat pump on its website. If you have a heat pump with a different badge, see our heat pump hot water guide.
Below is what AquaMAX's owner's guides say you can safely check, and when it's a job for a licensed tradesperson. We're an independent licensed plumbing and gasfitting business, not AquaMAX's service agent. If your unit is still under the maker's warranty, contact AquaMAX first through aquamax.com.au.
First checks you can safely do
Start by working out which type you have. The rating label on the side of the unit shows the model and whether it runs on gas or electricity.
- Electric units: check the switchboard. Look for an isolating switch labelled "HOT WATER" or "WATER HEATER" and make sure it's on. Check the circuit breaker or fuse for the water heater too. If a breaker keeps tripping, leave it off and call a licensed electrician or plumber. Don't keep resetting it.
- Electric units: think about the tariff. AquaMAX's guide explains that units on an off-peak tariff only heat during set hours. If you've used a lot of hot water, it may simply run out until the next heating period. On twin element models, the top (booster) element needs power all the time to work properly.
- Gas units: check the gas is on. Make sure the gas isolation valve near the heater and the valve at the meter are open. Try another gas appliance, such as the cooktop. If nothing gas in the home works, contact your gas supplier.
- Gas units: check the pilot. AquaMAX gas storage units use a standing pilot flame that lights the main burner. If the pilot has gone out, the water won't heat. See the relighting section below.
- Look at the relief valve. A small drip while the unit is heating is normal. A steady or heavy flow isn't. If hot water is pouring out, turn the unit off (gas control to off, or the switch at the switchboard) and call a plumber.
- Think about usage. Extra guests, long showers or a new spa bath can empty a storage tank faster than it can reheat.
If you smell gas at any point, don't try to light anything. Turn the gas off at the meter, open windows and doors, don't use switches, phones or flames near the area, leave and call a licensed gasfitter. For a leak at the meter, call Jemena on 131 909.
Common causes of no hot water or lukewarm water
| Symptom | AquaMAX type | Likely causes | Who fixes it |
|---|---|---|---|
| No hot water at all | Gas storage | Pilot out, gas valve closed, faulty thermocouple or gas control, gas supply problem | Owner can check gas and relight where the label allows; parts need a licensed gasfitter |
| No hot water at all | Electric storage | Switch or breaker off, failed element, failed thermostat, over-temperature cut-out has operated | Owner checks the switchboard; anything inside the unit needs a licensed person |
| Runs out quickly | Gas or electric storage | More hot water use, off-peak heating limits, booster element not powered, unit too small, failed element on a twin element model | Owner checks usage and switches; a plumber can test elements and advise on sizing |
| Lukewarm water | Gas or electric storage | Thermostat set low, tempering or mixing valve out of adjustment, sediment or scale build-up | Licensed plumber or electrical worker |
| Water pouring from the relief valve | Gas or electric storage | High mains pressure, faulty valve, thermostat fault | Turn the unit off and call a plumber |
| No hot water or temperature swings | Gas continuous flow | Low flow at the tap, gas supply, controller settings, a fault reported on the display | Owner checks gas, power and the controller; repairs need a licensed gasfitter |
Gas storage units
AquaMAX's current 5-star gas models (such as the G270SS, G340SS and G390SS) are outdoor units with stainless steel cylinders. The pilot flame stays lit and lights the main burner when the water needs heating. A pilot that won't stay lit usually points to a worn thermocouple, a faulty gas control or a poor gas supply. AquaMAX's guide says a healthy pilot is a small blue flame. A yellow or floating flame isn't right and should be looked at by a gasfitter.
Electric storage units
Electric AquaMAX units heat with one or two elements controlled by thermostats. When an element fails, a single element unit stops heating. A twin element unit may still heat a little but run out much faster. AquaMAX also fits an over-temperature cut-out. Its guide is clear that if this cut-out operates, it must not be reset by the owner. The heater needs to be checked by a qualified person, because a tripped cut-out usually means something else has gone wrong.
Gas continuous flow (Pro-Tec)
AquaMAX's Pro-Tec continuous flow model is sold through one plumbing retailer, so it's less common. Continuous flow units only fire up when enough water flows through them, so a low-flow tap or a blocked aerator can stop them heating. If your unit shows a code on the controller, write it down or take a photo. We haven't been able to confirm the code meanings from AquaMAX's published material. Check the manual for your model or tell us the code when you call, and we'll diagnose it on site.
Relighting the pilot on an AquaMAX gas storage unit
AquaMAX publishes lighting instructions for its gas storage heaters in the owner's guide and on the unit, and has a relight video for its 4 star gas storage model on its website. If you're comfortable following the maker's instructions for your model exactly, relighting the pilot is something the owner can do. Our step-by-step pilot relight guide explains the general process and safety points.
- Only relight if there's no smell of gas.
- Follow the instructions on your unit's label, step by step, including the waiting time after turning the control off.
- If the gas control knob won't turn by hand, or the unit looks damaged, AquaMAX says not to try. Call a licensed gasfitter.
- If the pilot lights but goes out again when you let go, or won't light after a couple of tries, stop. That points to a part that needs replacing.
Electric AquaMAX units have no reset button for owners. The thermostats and cut-out sit behind a cover with exposed 240-volt wiring, and AquaMAX says only a qualified person should remove that cover.
When it's a job for a licensed plumber or gasfitter
Pilot won't stay lit
A thermocouple, gas control or pilot assembly issue is gas work and must be done by a licensed gasfitter.
Electric unit not heating
Testing and replacing elements and thermostats means working inside the unit near live parts. That's for a licensed person.
Relief valve running
A steady flow can mean high mains pressure or a worn valve. A plumber can test the pressure and fit a pressure limiting valve if needed.
Water leaking from the tank
A leak from the cylinder itself can't be repaired. Turn the unit off and call us to talk about replacement.
Breaker keeps tripping
This can be an element fault or a wiring problem. Leave it off and have it checked. Wiring beyond the unit is a job for an electrician.
Gas smell or scorch marks
Turn the gas off and call a licensed gasfitter. Don't relight the unit.
Repair or replace your AquaMAX?
Thermocouples, gas controls, elements, thermostats and relief valves can all be replaced, and a repaired unit can give years more service.
Replacement is usually the better choice when:
- The cylinder is leaking. Once the tank itself fails, it can't be fixed.
- The unit is well into its second decade and has needed several repairs.
- Your household has grown and the tank keeps running out, even when it's working properly.
- You want to change to a different type, such as continuous flow or a heat pump.
Replacement options
The simplest option is a like-for-like swap: a new gas or electric storage unit in the same spot, using the existing connections where they're still in good order. You can also look at gas continuous flow, which heats water as you use it, or a heat pump, which uses much less electricity than a standard electric tank. Our gas hot water and electric hot water pages explain the choices, and our guide to hot water system size helps you work out what you need.
A job nearby: gas storage to continuous flow in Maroubra
The problem: An old gas storage tank down the side of a Maroubra home stopped delivering hot water.
What we did: We explained the repair and replacement options and the systems that would suit. The owners chose a Rinnai continuous flow unit. We removed the old tank, wall-mounted the new unit, upsized the copper pipework and replaced the gas regulator at the meter so the unit gets enough gas.
The result: Reliable hot water at every tap.
What affects the cost
Every job is different, so we look first and then give you a fixed price before we start. The main things that affect it are:
- Whether it's a repair (and which part) or a replacement.
- Gas or electric, and the size and type of any new unit.
- Access to the unit, such as a narrow side path or a tight cupboard.
- Extra work needed to meet current standards, such as a tempering valve, isolation valves, new pipework or a larger gas supply for continuous flow.
- Removal and disposal of the old tank.
What to have ready when you call
- A photo of the rating label on the side of the unit showing the model and serial number.
- Whether it's gas or electric, and roughly how old it is.
- What's happening: no hot water, lukewarm, running out, or water leaking.
- Any code showing on a continuous flow controller.
- What you've already checked, such as the switchboard or the pilot.
Local notes for Eastern Suburbs homes
Units close to the coast in Maroubra, Malabar, Coogee and La Perouse cop salt air, which can speed up corrosion on outdoor fittings, gas controls and jackets. Many older brick homes still have original copper or galvanised pipework, and joining a new unit to old pipe sometimes means replacing a short section. On the Botany side, sandy ground can let concrete bases and paths shift over time, so we check the unit is sitting level and secure.
Maintenance tips to keep your AquaMAX heating
- Every six months, gently lift and lower the relief valve easing lever, as AquaMAX recommends. Stand clear, as the water is hot. If water doesn't flow when you lift it, have it checked.
- Have the relief valve replaced at least every five years, as AquaMAX's guides advise.
- Electric units: AquaMAX recommends a major service every five years, including an anode check.
- Gas units: AquaMAX recommends a yearly check by a qualified person and a major service at six years.
- Don't turn the thermostat below what the maker allows. Stored water must be kept at 60°C or more to control legionella. A tempering valve keeps bathroom water at a safe temperature.
Our Priority Plan includes a free annual health check, 10% off for the year and priority booking, which makes it easy to keep on top of these checks.
What happens when you call
Tell us what's going on
Call or send a quick form. A photo of the unit's label and any code on the display helps us come prepared. No call-out fee.
Options and a fixed price first
We find the cause, explain repair and replacement options and give you a fixed price for each before any work starts.
Fixed, tested and backed
We do the work, test it, clean up, and back our workmanship with a lifetime labour warranty.
Why Eastern Suburbs homeowners call us
- Based in Matraville, a short drive from homes across the Eastern Suburbs
- Rated 5.0 from 110 Google reviews
- Free quotes, with options and a fixed price before any work starts
- Lifetime labour warranty on our workmanship
- Licensed plumbers, drainers and gasfitters (Lic. 398171C)
AquaMAX hot water questions
Why is my AquaMAX gas hot water not heating?
The most common reason is that the pilot flame has gone out. Check the gas is on at the meter and the isolation valve, and try another gas appliance. If there's no gas smell, you can relight the pilot by following the instructions on the unit. If it won't light or won't stay lit, a licensed gasfitter needs to check the thermocouple and gas control.
Why is my AquaMAX electric hot water not working?
Check the hot water switch and breaker at the switchboard first. If you're on an off-peak tariff, the unit only heats at set times, so it may have run out. If the power is on and there's still no hot water, the element, thermostat or over-temperature cut-out is the likely cause, and these need a licensed person.
Does an AquaMAX electric hot water system have a reset button?
There's an over-temperature cut-out, but AquaMAX's guide says owners must not reset it. It sits behind a cover with live wiring, and if it has tripped there's usually an underlying fault. Have a qualified person check the unit.
Is my AquaMAX relief valve meant to drip?
A small amount of water while the unit is heating is normal. AquaMAX puts it at roughly one fiftieth of the hot water you use. A steady stream or heavy flow is not normal, so turn the unit off and call a plumber. Our relief valve guide has more detail.
What do the error codes on an AquaMAX continuous flow mean?
We haven't been able to confirm AquaMAX's code meanings from its published material, so we won't guess. Note the code exactly, check the manual for your model, and let us know when you call so we can come prepared.
Who makes AquaMAX hot water systems?
AquaMAX is part of Rheem's group of brands and is made by Rheem at its Moorabbin factory in Victoria. The brand began in 1988.
My AquaMAX is still under warranty. Who should I call?
Contact AquaMAX first through aquamax.com.au. We're an independent licensed plumbing business, not AquaMAX's service agent. Once the warranty has finished, or if you'd rather an independent opinion, we're happy to help.
Should I repair or replace my old AquaMAX?
If the tank is leaking, it needs replacing. If it's a part like a thermocouple, element, thermostat or valve, repair is often good value, especially on a younger unit. We'll explain both options and give you a fixed price for each before any work starts.
See our hot water repairs and replacement page, compare gas hot water and electric hot water systems, or get a hot water quote. We look after homes nearby including Maroubra, Matraville and Randwick.