★★★★★ 5.0 from 100+ Google reviews · Your Sydney Plumber

Thermann hot water reset button: what it is and when to leave it alone

Thermann electric storage water heaters have a combined thermostat and over-temperature energy cut-out mounted behind the electrical cover, and the reset button is on that thermostat. Thermann's manuals say the cover should only come off with a licensed tradesperson doing the work, and that the cut-out must not be reset until the heater has been serviced by a licensed tradesperson. Owners can check the switchboard and their tariff, but pressing the reset is a job for a licensed person.

Thermann is the hot water brand sold through Reece, so you'll find plenty of them in Sydney homes: small and large electric tanks, smart electric models, gas storage, continuous flow and heat pumps. When one goes cold, people often go hunting for a reset button, but Thermann treats a tripped cut-out as a sign of a possibly dangerous situation, not a nuisance to clear. Here's what Thermann's manuals say, what you can safely check, and how each Thermann type differs.

We're an independent, licensed plumbing business based in Matraville, looking after Thermann electric, gas and heat pump systems in homes across the Eastern Suburbs and Botany Bay. We find the cause, give you options and a fixed price before any work starts, and there's a $0 call-out fee.

Checks you can make before calling anyone

These checks come from Thermann's own owner material. None need a cover removed or a tool.

  1. Look at the switchboard. Thermann's first check is that the circuit breaker for the water heater hasn't tripped. If you switch it back on and it drops out again, leave it off.
  2. Think about off-peak. If your Thermann runs on a timed tariff such as off-peak or controlled load, it only heats during set hours. Thermann's advice is to make sure that tariff is working properly. After heavy use, the tank may just be waiting for its next heating period.
  3. Smart electric models: open the app. For the Thermann Smart range, the owner's guide says to check the Thermann Control app hasn't left the heater in Holiday mode, on a Schedule, or switched off.
  4. Make sure water is getting in. Check the mains is on and the cold water isolation valve into the heater is open.
  5. Look around the base. A puddle under the tank, rust marks, or water running constantly from the relief valve drain line are worth photographing for when you call. Thermann notes that continuous leakage from the relief valve may point to a problem with the heater.

If the water is still cold after those checks, the cause is inside the unit and needs a licensed person.

Where the reset button is on a Thermann electric tank

Across the Thermann electric storage range, from the compact 25 and 50 litre tanks up to the large models of 80 to 400 litres, the heater is fitted with a combination thermostat and over-temperature energy cut-out. It sits on the side of the tank behind the electrical (element) cover. The reset button is part of that thermostat.

Here's what the manuals say for owners:

  • Electrical covers should only be removed by a licensed tradesperson.
  • Power must be fully disconnected at the isolation switch or switchboard before anyone opens the element cover, because there is live power underneath it.
  • The over-temperature energy cut-out must not be reset until the heater has been serviced by a licensed tradesperson.
  • The cut-out must not be tampered with or removed, and replacing it is a job for a licensed tradesperson or the manufacturer.

So we won't walk you through taking the cover off. It's a real shock risk, and resetting a cut-out without finding out why it tripped can leave a faulty thermostat in charge of very hot water.

What usually trips a Thermann cut-out

Thermann's FAQ names the element and thermostat as the likely suspects and says a licensed plumber should test them. Only testing on site confirms the cause.

What you noticeLikely areaWho looks at it
No hot water, breaker still onCut-out has tripped, often because the thermostat stuck on and overheated the waterLicensed plumber or electrician
Breaker trips as soon as it's resetElement has failed or is leaking to earth, sometimes from age or scale build-upLicensed plumber or electrician
Hot water returns, then stops againThermostat or wiring fault still present after a resetLicensed tradesperson to test and replace parts
Water noticeably hotter than normalThermostat fault, or the tempering valve isn't controlling bathroom temperatureLicensed plumber
Cold after a stormTripped breaker or surge damageCheck the switchboard, then call us

Thermann Smart electric: codes instead of guesswork

The Thermann Smart electric heaters have a display and the Thermann Control app, and the owner's guide lists a few codes. Code I2 simply means the antibacterial cycle has started, and no action is needed. For an E2 code, the guide suggests switching off and on at the isolation switch and contacting customer service if it comes back. For an I1 code, which relates to a very high probe temperature, the guide says to contact customer service. For any other code, note it down and call for service.

Thermann continuous flow: read the controller

Gas continuous flow units such as the Thermann R-Series (17R, 21R and 26R) have no reset button. They show a code on the unit or the remote controller instead. The R-Series owner's manual lists these, along with what an owner can safely do:

CodeWhat the manual says it meansOwner step
11Ignition failureCheck the gas valve is open, turn the unit off with the Operation button, open a hot tap, then turn it back on
LoWater flow too low for the burner to lightOpen the tap further or turn on another tap
L1, L2, L3Incoming water already too hot for the burner to lightCan show for up to an hour after a tap is turned off
FPNot a fault: freeze prevention is runningNo action needed
90 (901, 903, 908)Abnormal combustionIf it keeps showing, call a licensed gasfitter or customer service
902Abnormal combustion with low gas pressureA licensed plumber needs to check the gas pressure
99Abnormal combustionCall a licensed gasfitter or customer service

The manual also says the unit's power must stay on for frost protection to work. If you have a different Thermann continuous flow model, the codes may differ, so check your owner's manual.

Thermann gas storage: relighting the pilot

Thermann gas storage heaters, such as the 4 star 135 and 170 litre models, don't have a reset button either. The gas control valve does the thermostat's job and has built-in over-temperature cut-outs, and Thermann says it must not be tampered with or bypassed. If the valve's safety shutoff has activated, the manual says to wait 60 seconds for it to reset.

Thermann expects the installer to show the owner how to light the heater, and the lighting steps are in the owner's guide and on the unit. The main safety points from the manual:

  • Never try to light it if the pilot is out and the knob is still in the ON position. Turn the knob to off first.
  • Wait five minutes after turning it off so any unburnt gas can clear, and wait again before each new attempt.
  • Follow the steps on the label exactly, including how long to hold the knob down once the pilot lights.
  • Thermann recommends setting 6, roughly 60°C.

Before you start, make sure the gas is on at the meter and the isolation valve, and that your other gas appliances work. If the pilot won't stay alight, keeps going out, or you'd rather not do it, stop and call a licensed gasfitter. Our pilot relighting guide has more detail.

If you smell gas: turn the gas off at the meter, open doors and windows, don't use light switches, phones or flames nearby, leave the house and call a licensed gasfitter. For a leak at the meter, call Jemena on 131 909.

Thermann heat pumps

The Thermann integrated heat pump (for example the 270 litre model) also has an over-temperature energy cut-out, and the rule is the same: it isn't reset until a licensed tradesperson has serviced the heater. Owners can check the breaker, confirm any controlled load tariff and timers are working, keep the area around the unit clear so air can flow, and look at the controller for a code. Note the code and call for service. Water dripping from the condensate drain while it runs is normal. See our heat pump guide.

When to call a licensed plumber, gasfitter or electrician

  • Any time a cover needs removing, including to reach the reset button
  • A cut-out that has tripped, or trips again after a reset
  • A breaker on the hot water circuit that won't stay on
  • Testing or replacing an element or thermostat
  • A pilot that won't stay lit, a repeating combustion code, or any smell of gas
  • A relief valve running constantly rather than dripping a little while heating
  • Wiring, circuit or switchboard faults beyond the power point, which need a licensed electrician

Still under warranty? Contact Thermann's customer service first, using the details in your owner's manual or warranty card, and have the model and serial number from the compliance plate and proof of the installation date ready. We're an independent licensed plumbing business and not Thermann's service agent, so going to Thermann first protects your claim. If it's out of warranty or the fault isn't covered, we're glad to help.

Fix it or replace it?

A tripped cut-out doesn't automatically mean a new heater. Elements and thermostats can often be replaced on a tank that's otherwise in good shape. These are the things that tip the balance:

Leaking tank

A leak from the inner tank can't be repaired, so the heater has to be replaced.

Age

On a heater that's been in service many years, a new element may not be money well spent. We'll give you a straight answer.

Same fault again

Repeat failures or heavy corrosion around fittings usually make replacement the better choice.

Running out

If more people now live in the home, repairs won't add capacity. Our sizing guide helps.

A job nearby

Electric hot water replacement, Matraville

The problem: An electric hot water heater had come to the end of its working life.

What we did: We removed the old heater, poured a new concrete base and installed a new Rheem 80-litre electric heater. We also fitted a new Duo isolation valve and a new tempering valve, and replaced sections of the hot and cold copper pipework.

The result: The system was tested and commissioned, with tempered water supplied to the bathroom.

That was a Rheem, not a Thermann, but the steps are similar for any worn-out electric tank.

Choosing a replacement

  • Another electric storage tank, Thermann or another brand, in the same spot. More on our electric hot water page.
  • A heat pump, which uses much less electricity than an element to heat the same water, where there's room and airflow outdoors.
  • Gas storage or continuous flow, if your home has a suitable gas supply. See gas hot water.

We'll price each option that suits your home, so the choice is yours.

What affects the cost

  • A repair to an element or thermostat versus a new heater
  • The type and size of system you choose
  • How easy the heater is to reach: side passages, cupboards or stairs
  • Whether the base, valves, tempering valve or pipework need bringing up to current standards

You'll have a fixed price before any work starts.

Eastern Suburbs conditions

Near the beach in Maroubra, Coogee and Malabar, salt air works on outdoor covers, valves and fittings faster than further inland. Older homes around Matraville and Randwick often need pipe sections replaced when a tank is swapped. Where a heater stands in a wet spot, Thermann says a plinth should go under it.

Looking after your Thermann

  • Every six months, gently lift the relief valve easing lever and let it flow for a few seconds, then lower it carefully. Thermann's manuals warn that skipping this can be dangerous. Stand clear of the hot water.
  • A small drip from the relief valve while heating is normal. Never block it or replace it with a different valve.
  • Thermann recommends a five-year service by a licensed tradesperson, including a new relief valve and anode, and every three years where the water is hard.
  • Gas storage models also get a yearly check from a licensed tradesperson, covering the relief valve, gas control and thermocouple.
  • Leave temperature adjustments to a licensed plumber, as Thermann's FAQ advises.

What happens when you call

1

Tell us what's going on

Call or send a quick form. A photo of the unit's label and any code on the display helps us come prepared. No call-out fee.

2

Options and a fixed price first

We find the cause, explain repair and replacement options and give you a fixed price for each before any work starts.

3

Fixed, tested and backed

We do the work, test it, clean up, and back our workmanship with a lifetime labour warranty.

Why Eastern Suburbs homeowners call us

  • Based in Matraville, a short drive from homes across the Eastern Suburbs
  • Rated 5.0 from 110 Google reviews
  • Free quotes, with options and a fixed price before any work starts
  • Lifetime labour warranty on our workmanship
  • Licensed plumbers, drainers and gasfitters (Lic. 398171C)

Thermann reset button questions

Where is the reset button on a Thermann electric hot water system?

On the combined thermostat and over-temperature energy cut-out, behind the electrical cover on the side of the tank. Thermann says only a licensed tradesperson should remove that cover, with the power fully disconnected.

Can I press the Thermann reset button myself?

Thermann's manuals say not to reset the cut-out until the heater has been serviced by a licensed tradesperson. There's live power behind the cover, so please leave it to a licensed person.

Why has my Thermann cut-out tripped?

It trips when the water gets hotter than it should, which usually points to a thermostat fault. Element or wiring problems, or moisture in the element compartment, can also be involved. Testing on site finds the real cause.

What should I check first if my Thermann has no hot water?

Check the circuit breaker hasn't tripped, that any off-peak tariff is working, and on Smart models that the app isn't set to Holiday, a Schedule or off. Then check the water is on and look for leaks.

Does a Thermann continuous flow unit have a reset button?

No. It shows a code on the unit or controller. On the R-Series, code 11 means ignition failure and Lo means not enough flow. Persistent combustion codes need a licensed gasfitter.

How do I relight a Thermann gas storage pilot?

Follow the lighting instructions on the unit and in the owner's guide. Turn the knob off and wait five minutes before each attempt. If the pilot won't stay lit, or you smell gas, stop and call a licensed gasfitter.

My Thermann is under warranty. Who do I call?

Contact Thermann's customer service first, using the details in your manual, with the model and serial number and proof of the install date. We're independent and not Thermann's service agent. If it isn't covered, we can help.

Is my Thermann worth repairing?

Often, if the tank isn't leaking. A new element or thermostat can get a sound tank going again. A leaking tank needs replacing. We'll give you both options with a fixed price before starting.

See our hot water repairs and replacement page, electric hot water, gas hot water and the Dux reset button guide. Local pages: Matraville, Maroubra, Coogee and Botany. Ready to go? Get a hot water quote.

Call 0401 758 373Free quote