Dux hot water reset button: where it is and why it trips
On a Dux electric storage hot water system, the reset button is part of the combination thermostat and over-temperature energy cut-out, which sits behind the electrical cover on the tank. Dux's owner's manuals say that cover should only be removed by a licensed tradesperson with the power isolated, and that the cut-out should not be reset until the heater has been serviced by a licensed tradesperson. So it isn't a button for the owner to press.
If your Dux has gone cold, it's natural to go looking for a reset button. Plenty of websites tell you to take the cover off and push it. We'd rather tell you what Dux actually says, what you can safely check yourself, and why the cut-out tripping is a warning sign, not the fault itself. The cut-out is there to stop the water getting dangerously hot. When it trips, something has usually gone wrong with the thermostat, the element or the wiring, and pressing reset without finding out why can leave a fault in place.
We're an independent, licensed plumbing business based in Matraville, working on Dux electric, gas and heat pump water heaters across the Eastern Suburbs and Botany Bay. We find the cause, give you options and a fixed price before any work starts, and there's a $0 call-out fee.
First checks you can safely do
These are the checks Dux's own troubleshooting advice points owners to. None of them need a cover removed or a tool.
- Check the switchboard. Look for a tripped circuit breaker or safety switch on the hot water circuit. If it trips again straight away, leave it off and call us. A breaker that keeps tripping points to an electrical fault such as a failed element.
- Check the power point or isolating switch beside the tank (if your unit has one) is switched on.
- Think about your tariff. Many Dux electric units run on off-peak or controlled load power, which only heats at set times. If you've used a lot of hot water, it may simply need the next heating period. If you've recently changed energy retailer or had meter work done, check the timer or controlled load is still working with your energy company.
- Run a hot tap a little longer. Cold water sitting in the pipe has to clear first, especially at taps a long way from the tank.
- Check the water is on. Make sure the main water valve and the cold water isolation valve going into the heater are open.
- Look for leaks. Water pooling under the tank, a steady stream from the relief valve drain, or rust staining at the base are all worth a photo for when you call.
If those all check out and you still have no hot water, the next step is inside the unit, and that's a job for a licensed person.
Where the reset button is on a Dux electric storage unit
Dux electric storage heaters, including the Proflo range in sizes from 25 to 400 litres, use a combined thermostat and over-temperature energy cut-out. It is mounted on the tank behind the electrical cover. The reset button is on that thermostat. When the cover is off, the terminals and wiring behind it can be live at full mains voltage.
Dux's manuals are clear on two points. First, electrical covers should only be removed by a licensed tradesperson, and only after the power to the heater has been safely isolated. Second, the over-temperature cut-out should not be reset until the heater has been serviced by a licensed tradesperson. Dux also says the thermostat and cut-out must only be replaced by a licensed tradesperson or the manufacturer.
That's why we don't give step-by-step instructions for pressing it. Please don't remove the cover or poke anything behind it. It isn't worth the risk of an electric shock, and resetting a cut-out that tripped for a reason can let a faulty thermostat keep heating the water.
Why a Dux cut-out trips
The cut-out is a safety device. It trips when the water in the tank gets hotter than it should. The most common reasons we see are below, but the actual cause needs testing on site.
| What's happening | What it can mean | Who handles it |
|---|---|---|
| Cut-out tripped, no hot water | The thermostat may have stuck on and let the water overheat, so the cut-out switched the element off | Licensed plumber or electrician |
| Breaker trips at the switchboard | An element that has failed or shorted to earth, often from age or scale | Licensed plumber or electrician |
| Cut-out trips again soon after a reset | A faulty thermostat or a wiring problem is still there | Licensed tradesperson to test and replace parts |
| Water much hotter than usual at the tap | Thermostat fault, or a tempering valve that isn't doing its job | Licensed plumber |
| Lukewarm water only | A failed element, a thermostat fault, or a heater too small for the household | Licensed plumber |
| No hot water after a power outage or storm | Possibly a tripped breaker or a power surge damaging the thermostat | Check the switchboard first, then call us |
Moisture getting into the electrical compartment can also cause trouble. A leaking tank or a corroded fitting near the element can let water reach the thermostat and wiring, which is another reason a cover should never be left off or the unit run with panels removed.
Dux gas storage: no reset button, but you may be able to relight the pilot
Dux gas storage heaters, such as the Prodigy 4 and 5 star models, don't have a reset button like the electric units. The gas control valve acts as the thermostat and has its own over-temperature cut-outs, which Dux says must never be tampered with or bypassed.
What Dux does allow is for the owner to relight the pilot, following the lighting instructions on the unit and in the owner's manual. The key safety points from Dux: never try to light the pilot if it has gone out while the knob is in the ON position, turn the knob off and wait five minutes before each attempt so any unburnt gas can clear, keep your face back from the burner, and once it's lit set the knob back to the normal setting (Dux recommends at least setting 6, which is about 60°C). Our guide to relighting a hot water pilot walks through it.
Before relighting, check the gas is on at the meter and the isolation valve, and that your other gas appliances are working. If the pilot won't stay lit, goes out often, or you're not comfortable doing it, stop and call a licensed gasfitter. A pilot that keeps going out often points to a thermocouple, gas supply or control valve problem.
If you smell gas: turn the gas off at the meter, open doors and windows, don't use light switches, phones or flames near the area, leave the house and call a licensed gasfitter. For a leak at the meter, call Jemena on 131 909.
Dux heat pumps
Dux's current heat pumps are sold as the Ecosmart range (Dux's old Airoheat web address now points to it). The Ecosmart manual we checked also has an over-temperature energy cut-out on the element thermostat, with the same rule: don't reset it until a licensed tradesperson has serviced the heater. For owners, Dux suggests checking the power supply breaker, checking the mode in the Dux app, and making sure the side air grills aren't blocked. Water dripping from the condensate drain while it runs is normal. Our heat pump hot water guide covers more.
When it's a job for a licensed plumber or electrician
- Any time the electrical cover needs to come off, including to look at or press the reset button
- A cut-out that has tripped, or trips again after being reset
- A breaker that keeps tripping on the hot water circuit
- Testing or replacing an element or thermostat
- Any gas part, a pilot that won't stay lit, or a smell of gas
- A relief valve that runs constantly rather than dripping a little while heating
- Water leaking from the tank itself
- Electrical work beyond the power point, such as the circuit or switchboard, which is for a licensed electrician
Under warranty? Contact Dux first, with your model and serial number from the compliance label and a record of the installation date. We're an independent licensed plumbing business, not Dux's service agent, so going to Dux first protects any warranty claim. If the unit is out of warranty, or Dux says the fault isn't covered, we're happy to help.
Repair or replace?
A tripped cut-out on its own doesn't mean the heater is finished. A thermostat or element can often be replaced on a tank that is otherwise sound. Things that push it towards replacement:
Tank is leaking
Once the inner tank leaks, it can't be repaired. The heater needs replacing.
Older unit
A heater well into its second decade with a failed element may be nearing the end. We'll tell you honestly if a repair is worth it.
Repeat faults
If the same parts keep failing, or there's heavy corrosion around the fittings, replacement often makes more sense.
Not enough hot water
If the household has grown, a repair won't fix a tank that's too small. See our size guide.
A job nearby
Electric hot water replacement, Matraville
The problem: An electric hot water heater had reached the end of its life.
What we did: We disconnected and removed the old heater, poured a new concrete base, and fitted a new Rheem 80-litre electric heater in the same spot. We fitted a new Duo isolation valve and a new tempering valve, and replaced sections of the hot and cold copper pipework.
The result: Tested and commissioned, with tempered water to the bathroom.
This was a Rheem rather than a Dux, but it's a fair picture of what an electric storage replacement involves when a tank has had its day.
Replacement options
- Like-for-like Dux electric storage. Often the simplest swap, using the same spot and connections. See our Dux hot water page.
- Another electric storage brand, if it suits the space and your tariff. More on our electric hot water page.
- Heat pump, which uses less electricity than a standard element to heat water, if there's room and airflow outside.
- Gas storage or continuous flow, where the home has a suitable gas supply. See gas hot water.
We'll explain the options that genuinely suit your home and give you a fixed price for each, so you can choose.
What affects the cost
- Whether it's a repair (thermostat or element) or a full replacement
- The type and size of the new system
- Access to the heater, such as a tight side passage, an internal cupboard or stairs
- Whether the base, valves, tempering valve or pipework need updating to meet current standards
- Electrical changes needed for a different type of system
- Removal and disposal of the old tank
Every job gets a fixed price before we start, so there are no surprises.
What to have ready when you call
- A photo of the compliance label on the tank showing the model and serial number
- Roughly how old the heater is, or the install date if you have it
- Whether a breaker has tripped, and whether it trips again
- Any water around the base or from the relief valve drain
- For a heat pump, any error showing in the Dux app
Local notes for the Eastern Suburbs
Hot water systems close to the coast in suburbs like Maroubra, Malabar and Coogee are exposed to salt air, which can speed up corrosion on outdoor fittings, covers and valves. Many older brick homes around Matraville, Randwick and Kensington still have original copper or galvanised pipework near the heater that may need sections replaced when a tank is changed. On the sandy ground towards Botany and Eastgardens, a solid, level base under a storage tank matters, and Dux recommends a plinth where conditions are wet.
Maintenance tips
- Dux recommends lifting the relief valve easing lever gently at least every six months to check it flows freely. Let it snap back carefully and stand clear of the hot water.
- A small drip from the relief valve while heating is normal. Don't tamper with it, block it or swap it for a higher-rated valve.
- Dux recommends a licensed service around every five years, including replacing the relief valve and checking the anode, and more often in hard water areas.
- Don't turn a storage thermostat below what Dux sets. Storage water needs to be held at 60°C or more to control legionella bacteria, and a tempering valve keeps bathroom water at a safer temperature.
What happens when you call
Tell us what's going on
Call or send a quick form. A photo of the unit's label and any code on the display helps us come prepared. No call-out fee.
Options and a fixed price first
We find the cause, explain repair and replacement options and give you a fixed price for each before any work starts.
Fixed, tested and backed
We do the work, test it, clean up, and back our workmanship with a lifetime labour warranty.
Why Eastern Suburbs homeowners call us
- Based in Matraville, a short drive from homes across the Eastern Suburbs
- Rated 5.0 from 110 Google reviews
- Free quotes, with options and a fixed price before any work starts
- Lifetime labour warranty on our workmanship
- Licensed plumbers, drainers and gasfitters (Lic. 398171C)
Dux reset button questions
Where is the reset button on my Dux electric hot water system?
It's on the combined thermostat and over-temperature cut-out behind the electrical cover on the tank. Dux says that cover should only be removed by a licensed tradesperson with the power isolated, so it isn't something to get to yourself.
Can I press the Dux reset button myself?
Dux's manuals say not to reset the over-temperature cut-out until the heater has been serviced by a licensed tradesperson. Behind the cover there are live electrical parts, so please leave it to a licensed person.
Why did my Dux cut-out trip?
It trips when the water gets too hot, usually because the thermostat has stuck on. Element faults, wiring problems or moisture in the electrical compartment can also be involved. Testing on site finds the real cause.
My Dux keeps tripping the breaker. What should I do?
Leave the breaker off and call a licensed plumber or electrician. A breaker that trips repeatedly on the hot water circuit often points to a failed element or another electrical fault.
Does a Dux gas hot water system have a reset button?
Not like the electric units. Dux gas storage models have a gas control valve with built-in safety cut-outs that must not be tampered with. If the pilot has gone out, you can relight it by following the instructions on the unit, as long as you're comfortable doing so.
Is my Dux worth repairing?
Often, if the tank isn't leaking. A new thermostat or element can bring a sound tank back to life. If the tank leaks, it needs replacing. We'll give you both options with a fixed price before any work starts.
My Dux is still under warranty. Who should I call?
Contact Dux first with your model and serial number and a record of the install date. We're an independent licensed plumbing business, not Dux's service agent. If it's out of warranty or not covered, we can help.
How hot should my Dux be set?
Storage water needs to be held at 60°C or more to control legionella. Dux says its thermostats don't go below 60°C, and adjustments should be made by a licensed plumber. A tempering valve keeps the water at bathroom taps at a safer temperature.
See our hot water repairs and replacement page, our Dux hot water page, electric hot water options and how to relight a hot water pilot. Local pages: Matraville, Maroubra and Randwick. Ready to book? Get a hot water quote.