Backflow testing in Banksmeadow 2019
Almost every business site in Banksmeadow has a backflow prevention device, and many have more than one. Sydney Water requires testable devices to be tested every year by an accredited backflow plumber, with the results sent to Sydney Water within two days. Industrial sites near Port Botany often have higher hazard connections, such as chemicals, process water, wash bays and fire services, so they usually need the testable kind. We're based a few minutes away in Matraville and we test devices at factory complexes along Beauchamp Road.
Backflow devices we test in Banksmeadow
Reduced pressure zone devices (RPZDs)
The high hazard device used on many industrial sites, often at the property boundary next to the meter.
Double check valves
Testable medium hazard devices on drinking water connections.
Fire service devices
Double check detector assemblies on sprinkler and fire hydrant connections.
Zone and individual devices
Devices on individual equipment, wash bays, chemical dosing and process lines inside the site.
New device installs
Supply and installation of the right device when a site's hazard changes or a device can't be repaired.
Food businesses
The backflow device at the boundary that Sydney Water requires for retail food businesses.
What backflow is and why it matters
Backflow is when water flows the wrong way, from a property back into the drinking water supply. It can happen when pressure in the main drops, for example during a main break or when firefighters draw heavily from a hydrant, or when a site's own pressure is higher than the main. On an industrial site, that water could carry chemicals, process water, detergents or anything else connected to the plumbing. A backflow prevention device stops it, using a one-way valve, an air gap or a break tank, so what's on your site stays on your site.
What Sydney Water requires
- If your property is connected to Sydney Water's water or recycled water pipes, you must have the right backflow containment device and keep it working.
- An accredited backflow plumber assesses the site's hazard rating, and installs, tests and registers testable devices.
- Testable devices must be tested every year, and the results sent to Sydney Water within two days of the test.
- Sydney Water keeps a register of testable devices and sends a yearly reminder when a test is due.
- If a device isn't tested or maintained, Sydney Water can test it and charge for it, restrict the water supply or disconnect it.
Hazard ratings in plain English
| Hazard rating | What it means | Typical device |
|---|---|---|
| High | A connection that could put something harmful into the water, such as chemicals or process water | Reduced pressure zone device, registered break tank or registered air gap |
| Medium | A connection that could affect the water's quality but isn't likely to harm health | Testable double check valve |
| Low | A connection with little risk, such as a typical office or house | Non-testable device; 20 mm and 25 mm meters have one built in |
| Not yet assessed | A site whose hazard hasn't been worked out | Treated as high until assessed |
Fire sprinkler and hydrant services need a testable double check detector assembly on each connection. A site with several units may have a device at the boundary for the whole complex and further devices inside individual units.
How an annual backflow test works
- We book a time that suits your site. Many tests need the water off for a short time, so for complexes and busy sites we often book a Saturday or early start.
- We find the device and check it's the right type for the site's hazard and still registered.
- We isolate the water and connect our test kit to the device's test points.
- We test each part: the check valves, the relief valve on an RPZD and the shut-off valves, against the required readings.
- We turn the water back on and check supply across the site.
- If it passes, we lodge the results with Sydney Water and give you a copy for your records. If it fails, we explain why and give you a fixed price to repair or replace it.
A recent backflow test nearby
Here's a recent annual test at a factory complex on Beauchamp Road in Matraville, just up the road from Banksmeadow.
Annual backflow test on a 50 mm RPZD, factory complex on Beauchamp Road, Matraville (nearby)
The problem: a factory complex on Beauchamp Road in Matraville, just up the road from Banksmeadow, has a 50 mm reduced pressure zone device (RPZD) protecting the water supply, and it was due for its annual test. Testing it meant turning off the water to every business in the complex.
What we did: we booked the test for a Saturday morning, when most units were closed, so no one lost water during a working day. We isolated the supply, ran the full test on the RPZD to confirm every valve and the relief port worked as they should, then turned the water back on and checked supply across the site.
The result: the device passed, the results were lodged with Sydney Water through its online portal, and the site got a compliance certificate for its records. The businesses opened on Monday without knowing anything had happened.
More local work is on our recent projects page.
Why devices fail a test
- Debris on the seats of the check valves, from sand, scale or rust in the water, so they don't seal fully.
- Worn rubber parts, such as seals, diaphragms and springs, that have aged.
- A relief valve on an RPZD that drips or won't open at the right pressure.
- Shut-off valves that won't close fully, so the test can't be done properly.
- Damage from frost, vehicles or a device that's been knocked.
Most failed devices can be repaired with a service kit. If a device is old, damaged or no longer suits the site's hazard, replacing it is often the better option, and we'll give you a fixed price for both.
Quick fix or long-term fix?
| Problem | Quick fix | Long-term fix |
|---|---|---|
| Device fails on worn seals | Service kit and retest | Plan replacement if the device is near the end of its life |
| RPZD relief valve dripping | Clean and service | Fit a strainer upstream if debris keeps causing it |
| Wrong device for the hazard | None | Replace with the correct device and register it |
| Device in a traffic path | Repair damage | Protect it with a cage or bollard, or relocate it |
| Water off for every test | Short planned shutdown | Fit a second device in parallel so one can be tested while the other supplies the site |
What affects the cost
- The number and type of devices on the site.
- Access: devices in pits, cages, high on walls or inside units.
- Timing: testing outside your business hours or on a weekend.
- Repairs: service kits, strainers or a replacement device.
- Lodging and records: included with every test.
You get a fixed price before any work starts.
Who's responsible?
- The property owner: making sure the right device is installed, tested every year and kept working. In a lease, the tenant may be asked to arrange it, so check your lease.
- Factory complexes: the boundary device for the whole complex is usually the complex's, while devices inside a unit belong to that unit.
- An accredited backflow plumber: assesses, tests and lodges the results.
- Sydney Water: keeps the register, sends reminders and audits a sample of installations.
Quick checks you can do
- Find your device. It's usually near the water meter at the boundary, in a cage or a pit.
- Check the reminder letter or email from Sydney Water for the due date.
- Look for water dripping from the device's relief port.
- Make sure the device isn't buried, overgrown or blocked by stock or pallets.
- Keep a copy of last year's test results with your site records.
Signs a device needs attention now
- Call soon if the relief valve on an RPZD is dripping or discharging, the device has been hit, or your test is overdue.
- Book a time if your annual test is coming up or you've had a reminder from Sydney Water.
Banksmeadow sites and backflow
| Type of site | Typical connections | Usually needs |
|---|---|---|
| Chemical, fuel and process sites | Process water, dosing, tanks | High hazard: RPZD, break tank or air gap |
| Factories and workshops | Wash bays, equipment, hose reels | Medium or high hazard, depending on what's connected |
| Warehouses with fire services | Sprinklers and hydrants | Testable double check detector assembly |
| Food businesses | Kitchen equipment, grease trap wash-down | Testable device at the boundary |
| Offices and showrooms | Toilets, kitchenettes | Usually low hazard, unless there's other equipment connected |
Banksmeadow, area by area
- Around the port and the terminals: large sites with high hazard connections and fire services.
- Industrial estates off Botany Road: factory complexes with a boundary device and devices in individual units.
- Warehouses and logistics yards: fire services and wash bays.
- Next door in Botany, Hillsdale and Matraville: we test devices at complexes along Beauchamp Road and in the surrounding estates.
Testing without stopping your site
Many backflow tests need the water off, even if only for a short time. On a factory complex, that means every business on site loses water. We plan around it: Saturday mornings or early starts when units are closed, a quick test and a careful restart so supply is back before anyone needs it. On sites where the water can't go off at all, the long-term answer is a second device fitted in parallel, so one can be tested while the other keeps supplying the site.
Keeping your records straight
After each test we lodge the results with Sydney Water and give you a copy. Keep them with your site's compliance records alongside fire service, TMV and other maintenance records. If you manage several units or sites, we can test them on the same day and keep the dates lined up so the reminders arrive together.
Backflow words explained
- Backflow: water flowing the wrong way, from a property back into the mains.
- Containment device: the device at the boundary protecting Sydney Water's supply from the whole site.
- Zone or individual device: a device inside the site protecting the rest of the plumbing from one area or piece of equipment.
- RPZD: reduced pressure zone device, a testable high hazard device with a relief valve.
- Double check valve: two check valves in a row; testable versions are used for medium hazard.
- Break tank and air gap: a physical gap between the supply and the water being used, so backflow can't happen.
New devices and changes to your site
If you're fitting out a new unit, adding a wash bay, connecting new equipment or changing how the site is used, the hazard rating can change, and so can the device you need. A licensed plumber installs the device and an accredited backflow plumber tests and registers it. We do both, so you deal with one business from the assessment through to the lodged test results.
Homes in Banksmeadow
Most homes don't need a testable device: the water meter has one built in. Homes with some rainwater tank top-up, irrigation or other connections can need one. If you have a device at home, we'll test it and lodge the results the same way. See our backflow testing page.
A backflow test, step by step on the day
- We arrive at the agreed time, sign in, and do any site induction you need.
- We confirm which devices are being tested and where the shut-off valves are, and let anyone affected know the water is about to go off.
- We check the device's tag or plate, its size, type and serial number, against Sydney Water's register.
- The supply is isolated and our calibrated test kit is connected to the device's test cocks.
- Each check valve is tested to make sure it holds, and on an RPZD the relief valve is tested to make sure it opens at the right point.
- The shut-off valves are checked to make sure they close fully, because a valve that lets by can make the test meaningless.
- The water is turned back on slowly, air is bled from the line, and we check that supply is back across the site.
- We complete the test report, lodge it with Sydney Water and send you a copy.
For a single device the test itself usually takes well under an hour. Most of the planning goes into making sure the water is off for as short a time as possible and at a time that suits the site.
Strainers and dirty water
Many failed tests in this area come down to debris: sand, scale and rust carried along the pipes and lodged on the valve seats. Sites on older water services, or where mains work has stirred up sediment, see it more often. A strainer fitted upstream of the device catches most of it before it reaches the valves. It needs cleaning from time to time, but it can be the difference between a device that passes every year and one that needs a service kit every time it's tested.
Protecting the device
Backflow devices at the boundary of industrial sites are often near driveways, gates and loading areas. They get hit by vehicles, buried by landscaping, covered with pallets or damaged by people climbing on them. A lockable cage or bollards keep them safe and easy to reach, and keeping the area clear means the test can be done quickly. If a device has been damaged, it needs repair and a retest before it can be relied on.
If you've just taken over a site
When a business moves into a new unit, the backflow test can fall through the cracks: the reminder goes to the old tenant or the owner, and nobody books it. If you've taken over a site in Banksmeadow and you're not sure when the device was last tested, give us a call. We'll find the device, check its registration and test it, so you're starting with a clean record rather than an overdue notice.
Other compliance testing on the same visit
If your site has thermostatic mixing valves on staff showers or hand basins, we can test and service them on the same visit as the backflow test, and look over the amenities, hot water and drains while we are there. One visit, one set of records, and less disruption for your staff. See our TMV testing page.
What to have ready before we arrive
- The Sydney Water reminder, or the device's details from last year's report, if you have them.
- Who to call on site, and whether there's an induction or sign-in.
- A time when the water can go off for a short while, and who needs to be told.
- Clear access to the device, with pallets, bins or vehicles moved away.
- Keys to any cage, pit or meter box.
Devices that sit inside a unit
In some factory complexes, the containment device at the boundary protects the whole complex, but individual units also have their own devices on equipment, wash bays or process lines. Those zone and individual devices belong to the unit, and if they're testable, they need their own annual test. A unit owner can easily miss them because the reminder for the boundary device goes to the complex. We'll check what's in your unit and test the lot.
Why a yearly test is worth doing properly
It's tempting to treat the annual test as paperwork, but the device is the only thing standing between your site's plumbing and the drinking water that your neighbours, the port and the homes on the Botany side all share. Valves that have sat closed for a year can stick, and a relief valve that's been dripping for months is telling you something. A careful test finds those problems while they're small, keeps your site on the right side of Sydney Water, and means that if something does go wrong in the main, your site isn't the one that contaminates it.
It also saves money. A device that's serviced when it first starts to wear usually needs a kit, not a replacement, and a test booked well before the due date can be planned for a quiet time rather than squeezed in around a busy week.
Why Banksmeadow businesses call us for backflow testing
- Based in Matraville, a few minutes from Banksmeadow
- Weekend and early starts when that keeps your site running
- Rated 5.0 from 110 Google reviews
- Options and a fixed price before any work starts
- Lifetime labour warranty on our workmanship
- Licensed plumbers, drainers and gasfitters (Lic. 398171C), with accredited backflow testers on the team
Backflow testing questions from Banksmeadow businesses
How often does a backflow device need testing?
Testable devices must be tested every year by an accredited backflow plumber, and when they're first installed.
Do you lodge the results with Sydney Water?
Yes. We lodge them with Sydney Water after the test and give you a copy for your records.
Will the water need to go off?
Usually for a short time. We can test on a Saturday or early in the day so your site, or the other businesses in your complex, aren't affected.
What happens if our device fails?
We explain why it failed and give you a fixed price to repair or replace it. Most can be repaired with a service kit and retested.
What's an RPZD?
A reduced pressure zone device, the testable device used for high hazard connections. It has two check valves and a relief valve that opens if pressure conditions could cause backflow.
Do fire services need backflow testing?
Yes. Sprinkler and hydrant connections need a testable double check detector assembly, and it must be tested every year.
Who is responsible, the owner or the tenant?
The property owner is responsible, but a lease may ask the tenant to arrange it. Check your lease.
We got a reminder from Sydney Water. What do we do?
Call us with the reminder and your site address, and we'll book the test.
Can you test several units on the same day?
Yes. If you manage a few units or sites, we can test them together.
What if our site's use changes?
The hazard rating may change, and with it the device you need. We'll assess it and fit and register the right device.
Do you do the plumbing for new devices too?
Yes. We install new devices as licensed plumbers and test and register them as accredited backflow testers.
Do you give a fixed price?
Yes, before any work starts.
More plumbing in Banksmeadow: our Banksmeadow plumber page, blocked drains, leak detection and hot water. Nearby: plumber Botany and Matraville. Guides: backflow testing and TMV testing.