On a Braemar gas heater, fault 07 (FC7) is the code you'll see most. Braemar's own instruction for it is the same across its wall furnace and remote control manuals: check the gas is turned on, then do a user reset. If it comes back, it's a service call. On Braemar ducted heaters, Seeley International describes FC7 as the heater trying to light but not detecting a flame. Codes 5, 9 and 19 go straight to a service call, and anything inside the heater is a job for a licensed gasfitter.

Braemar heaters are made by Seeley International. When a Braemar heater finds a problem it shuts itself down and flashes a fault code (Braemar calls it an FC number) on the control panel lights or on the remote. Braemar's manuals rarely say what each number means, but they do give a remedy for each: a simple check, a reset, or a call to a gasfitter. The lists also differ between Braemar ranges, so always check the manual that came with your heater before acting on a code.

We're an independent, licensed plumbing and gasfitting business based in Matraville, looking after gas heaters in homes across the Eastern Suburbs and Botany Bay. We find the cause, give you options and a fixed price before any work starts, and there's a $0 call-out fee.

Which Braemar heater do you have?

The code list you need depends on which Braemar heater you have. The model number is on the rating plate. Take a photo of it, along with the code that's showing.

Ecostar PowerFlue wall furnace

A flued gas heater built into or against a wall: the PWF30 (natural gas or propane) and PWF40 (natural gas). Codes flash on the front panel lights. Seeley says this line is now retired.

Space heater with the optional remote

Some Braemar Ecostar space heaters came with a remote. On a fault it flashes RESET and a number, and the heater's panel lights flash too.

Ducted gas heating

Braemar TQ, TH and TG ducted heaters show codes on the wall controller. Covered briefly below.

What about unflued or portable Braemar heaters? We couldn't find an unflued or portable Braemar heater, or a manual for one, on Braemar's or Seeley's websites. Braemar describes its wall furnaces as flued, with no emissions inside the home.

First checks you can safely do

These steps come from Braemar's manuals. None involve removing a panel, and Braemar says never run the heater with covers or guards off.

  1. Write down the code and the colour of the flashing lights. On the wall furnace, red lights show the code and green or orange show which reset to use.
  2. Check the gas is on at the meter. If it's been turned off, Braemar says contact your installer or gas supplier. On propane, check the cylinder isn't empty.
  3. Check the power. No lights at all? Check it's plugged in and the power point is on, then press ON/OFF.
  4. Check CHILD LOCK is off if it won't turn on.
  5. Turn the set temperature up a few degrees if the burner won't light.
  6. Clear the louvres and flue terminal. Several codes point to a blocked louvre or flue, so move anything against the heater and check the flue outside.
  7. Do one reset as below. If the code comes straight back, book a service.

If you smell gas, don't reset the heater or try to relight anything. Turn the heater off and turn the gas off at the meter, open doors and windows, don't use light switches, phones or anything that could spark or flame near the area, leave the house and call a licensed gasfitter. For a leak at the meter itself, call Jemena on 131 909.

Braemar fault codes and what to do

The table below sets out the remedies Braemar prints in two owner's documents: the remote control instructions for Braemar Ecostar space heaters, and the owner's manual for the Ecostar PowerFlue wall furnace (PWF30 and PWF40). Where a code isn't listed in one, or the remedy isn't clear in the version we checked, we say so. Codes and remedies can change between models and manual versions, so check the manual for your heater.

CodeSpace heater remote (Braemar's remedy)PowerFlue wall furnace (Braemar's remedy)When to call a gasfitter
FC 1Press RESET on the remoteService callWall furnace: now. Remote models: if it returns.
FC 2Check the flue terminal isn't blocked, then press RESETCheck your manualIf the flue is clear and it returns.
FC 5Service callService callStraight away.
FC 7Check the gas is turned on, then press RESETCheck the gas is turned on, user control reset. If persistent, service callIf the gas is on and it returns.
FC 9Service callTurn the power off and on. Service callIf a power cycle doesn't clear it.
FC 10Check the inlet and outlet louvres aren't blocked, then press RESETCheck the inlet and outlet louvres aren't blocked, user control reset. If persistent, service callIf the louvres are clear and it returns.
FC 11User resetUser control reset. If persistent, service callIf it returns after a reset.
FC 12User resetNot listedIf it returns after a reset.
FC 13Check the flue terminal isn't blocked, then press RESETCheck your manualIf the flue is clear and it returns.
FC 15Check the inlet and outlet louvres aren't blocked, then press RESETCheck your manualIf the louvres are clear and it returns.
FC 16Not listedTurn the power off and on. If persistent, service callIf a power cycle doesn't clear it.
FC 19Service callService callStraight away.

Braemar says to quote the fault code when you ask for service, as it may let the problem be sorted over the phone. If your code isn't here, don't guess: check your own manual or send us a photo of the display and rating plate.

Fault 07: the one most people search for

FC7 is in every Braemar list we checked, and the owner's step is always: make sure the gas is on, then reset. For Braemar ducted heaters, Seeley describes FC7 as ignition attempted with no flame detected (on TG and TH models, after three attempts). In plain terms, the heater is trying to light and giving up.

Sometimes it's simple, like the gas being off at the meter or a propane cylinder running low. If the gas is definitely on and the code keeps returning, Seeley's technical notes point to gas pressure, burner alignment, the spark igniter and the flame sensing probe. All of those are jobs for a licensed gasfitter.

How to reset a Braemar heater, the way Braemar says

  • Wall furnace, green light flashing: press and hold ON/OFF until the lights go off, then press ON/OFF again.
  • Still faulting, or orange and green flashing: turn the power off at the power point for 10 seconds, then back on.
  • Space heater with remote: follow the remedy for the code, then press RESET on the remote.
  • After a blackout: Braemar says the heater shuts down and needs a manual restart once power is back.

Braemar notes that if a fault repeats after a reset or power cycle, a service call may be needed. Don't remove covers or modify the heater: Braemar says installation and servicing are for authorised personnel only. A damaged power cord must be replaced by the manufacturer, its service agent or a similarly qualified person, and electrical work beyond the plug is for a licensed electrician.

Braemar ducted heating codes, briefly

If your heating comes through floor or ceiling vents, it's ducted. Seeley's technician notes describe FC7 as ignition attempted with no flame detected, FC11 as a loss of flame signal, and link FC10 on the TQ range to a heat exchanger over-temperature sensor and possibly restricted airflow. Braemar's owner checks for ducted heaters:

  • Set the thermostat above room temperature, then reset it OFF, ON, OFF, ON with a five second wait at each step.
  • Check the gas is on at the meter. If it's off, contact your installer or gas supplier.
  • Clean the return air filter (where fitted) at least every two weeks in the heating season. A vacuum cleaner will do it.
  • On propane, keep the cylinder at or above 30% full. Braemar warns low supply pressure can damage the heater, and that repair isn't covered by warranty.

Carbon monoxide and ventilation

A flued heater like a Braemar wall furnace sends combustion gases outside through the flue, which only works if the flue is sound and clear. That's one reason Braemar's two-yearly maintenance schedule includes the flue system and cowl. Carbon monoxide has no colour or smell.

  • Headaches, dizziness or nausea that ease away from the heater: turn it off, open doors and windows, get everyone outside and get medical advice. Have the heater checked before using it again.
  • Soot or staining around the heater or flue, or yellow, lazy flames: turn it off and call a licensed gasfitter.
  • Keep the flue terminal outside clear of plants and stored items.
  • Running an unflued heater of another brand? Follow its manual's ventilation rules exactly.

When it's a job for a licensed gasfitter

  • Codes 5, 9 and 19, which Braemar lists as a service call.
  • Any code that returns after one reset with gas, power and louvres checked.
  • A heater that clicks, tries to light and gives up again and again.
  • A gas smell, soot marks, or a damaged or loose flue.
  • Any work behind the covers: burners, ignition, sensors, pressure switches or the control board.

Under warranty? Call Braemar first. Seeley International handles Braemar warranty and service on 1300 650 644, or you can log a claim on its website with proof of purchase and service records. Braemar's manuals say the maintenance schedule must be checked every two years by a licensed technician and filled in, or the warranty can be void. We're an independent licensed gasfitting business, not Braemar's service agent, so going to Braemar first protects your claim. Out of warranty or not covered? We're happy to help.

Repair or replace?

One fault code doesn't mean the heater is finished. An ignition or sensing part on a sound heater is often worth repairing. Things that can tip it towards replacement:

Retired range

Seeley says the PowerFlue wall furnace line is no longer in production. We check parts for your model before recommending a repair.

Heat exchanger damage

Braemar lists the heat exchanger on its maintenance schedule. A damaged one is a safety issue and usually means replacement.

Repeat faults

If the same code keeps coming back after parts are changed, a new heater can make more sense.

If replacing makes sense, we'll explain the options that suit your home, including reusing the gas line and flue position. See our gas heater servicing page.

What affects the cost

  • A reset and clean, a single part like an igniter or sensor, or a bigger repair.
  • Parts availability for your model, especially a retired range.
  • Access to the heater and flue.
  • For a replacement, the new heater and any gas line or flue changes.
  • Whether Braemar's warranty still applies.

Every job gets options and a fixed price before we start, and there's a $0 call-out fee.

Local notes for Eastern Suburbs homes

Plenty of older homes and units around Matraville, Maroubra and Kensington still rely on a gas wall furnace in the hallway or living room, and many haven't had the two-yearly service Braemar asks for. Near the water in Malabar, Little Bay and Botany, salt air can corrode flue cowls and terminals faster, so check the outside of the flue each winter.

Keeping your Braemar heater running well

  • Book a licensed service every two years and keep the schedule in the manual filled in. Braemar recommends servicing continues after the warranty ends.
  • Clean the front cover and louvres with a damp cloth, with no solvents or abrasive cleaners.
  • Don't put anything on or against the heater, and keep furniture well back from the front.
  • Don't store chemicals or flammables near the heater or flue terminal, or spray aerosols near it while it's running.

What happens when you call

1

Tell us what's going on

Call or send a quick form. A photo of the unit's label and any code on the display helps us come prepared. No call-out fee.

2

Options and a fixed price first

We find the cause, explain repair and replacement options and give you a fixed price for each before any work starts.

3

Fixed, tested and backed

We do the work, test it, clean up, and back our workmanship with a lifetime labour warranty.

Why Eastern Suburbs homeowners call us

  • Based in Matraville, a short drive from homes across the Eastern Suburbs
  • Rated 5.0 from 110 Google reviews
  • Free quotes, with options and a fixed price before any work starts
  • Lifetime labour warranty on our workmanship
  • Licensed plumbers, drainers and gasfitters (Lic. 398171C)

Braemar gas heater fault code questions

What does fault 07 mean on a Braemar gas heater?

Braemar says check the gas is on and do a user reset, and book a service if it keeps returning. On Braemar ducted heaters, Seeley describes FC7 as ignition attempted with no flame detected. If the gas is on and it returns, a licensed gasfitter needs to check it.

How do I reset my Braemar wall furnace?

If the green light is flashing, press and hold ON/OFF until the lights go off, then press ON/OFF again. If the fault is still there, or the orange and green lights are flashing, turn the power off at the power point for 10 seconds and back on. If the code returns, stop and book a service.

Why does my Braemar heater keep showing fault 10?

Braemar's remedy for FC10 is to check the inlet and outlet louvres aren't blocked, then reset. If they're clear and FC10 keeps returning, it needs a licensed technician.

Which Braemar codes mean I should call straight away?

Braemar lists codes 5 and 19 as a service call, and code 9 on the wall furnace as a power cycle followed by a service call. Any code that returns after one reset, or any smell of gas, also means call a licensed gasfitter.

Can I fix a Braemar heater myself?

Only the checks Braemar gives owners: gas, power, child lock, set temperature, clear louvres and flue, wiping the outside with a damp cloth, and the reset steps. Servicing is for authorised personnel only.

How often should a Braemar heater be serviced?

Braemar's manuals say a qualified, licensed technician should check the items in the maintenance schedule every two years from installation, and fill in the schedule. Braemar recommends keeping this up after the warranty ends.

My Braemar is under warranty. Who do I call?

Call Seeley International, who handle Braemar warranty and service, on 1300 650 644 or log a claim on their website. We're independent, not Braemar's service agent, but happy to help once it's out of warranty or not covered.

Should I repair or replace my old Braemar wall furnace?

It depends on the fault, the heater's condition and whether parts are available, as the PowerFlue wall furnace line has been retired. We'll check it, explain both options and give you a fixed price for each before any work starts.

See our gas heater servicing and repair page, or get a gas quote in 30 seconds. We look after gas heaters and gas fitting in Matraville, Maroubra, Kensington and Botany, plus homes across the Eastern Suburbs. We also handle gas hot water and gas cooktop installation.

Call 0401 758 373Free quote